Accessories for Data Acquisition System MS5D, MS5

Included accessories:

Traceable calibration certificate from the manufacturer, instruction manual. Calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Example of calibration certificate.
Included is also communication cable for RS232, length 2 meters, free Windows program. Free program is available to dowload anytime. Program enables to control all logger functions and view and print the record in numerical format.

Optional accessories:

Please order required input modules or other accessories.
Program for data acquisition for monitoring system SWR006 Optional software for Windows - comfort graphic environment data acquisition, including on-line graph, automatic data download, remote Display mode on Internet-Ethernet network, storing data on the network, administration of users and passwords and many others ..
Accessories for data logger mounting
Larger photo of monitoring system holders MP013 Universal metal wall holders for data logger wall mounting. Package contains a pair of holders and 4 screws.
Larger photo of monitoring system holder MP012 Holder for data logger mounting to DIN 35mm rail. Package contains the holder and 6 screws.
Power sources
Larger photo of monitoring system source A1759 Universal ac/dc adapter 230V-50Hz/21Vdc/1A.
Larger photo of monitoring system source A1940 Universal ac/dc adapter 230V-50Hz/24Vdc/1A/24W for socket plug-in, switch-mode.
Larger photo of monitoring system source A5948 Power source 230V-50Hz/24Vdc/2,5A for DIN rail 35mm, dual terminals 24Vdc, switch-mode, including DIN rail of 100mm length.
Optional internal equipment
MP025 Built-in LAN interface for data logger connection to Ethernet network. Communication via: SNMP, SOAP, www pages. In case of limits exceeding alarm is activated and warning e-mail or SNMP trap are sent to specified addresses.



MP024 Built-in independent SMS port for GSM modem connection for SMS reception and sending. Enables to receive information from data logger by means of SMS messages - actual values, alarms, memory occupation and others - as a response to SMS query from user or in case of alarm creation at data logger.
Not necessary, if data logger is connected to the PC via GSM modem.
External communication converters
Larger photo of monitoring system converter MP021 Converter RS485/RS232 for serial port COMx at the PC side, including ac/dc adapter and terminator T485.
Larger photo of monitoring system converter MP022 Converter USB/RS485 for USB port at the PC side, including terminator T485. Powered from computer USB interface.
Larger photo of monitoring system converter MP023 Converter Ethernet/RS485 ncluding ac/dc adapter and terminator T485. Designed for several data loggers conencted via RS485 network for connection to the computer via Ethernet.
Accessories connectable to ALARM OUT output
Larger photo of data acquisition alarm MP026 External audio indication unit. Enables to signal alarm state acoustically at the location up to 50m from data logger. Audio unit is connected to data logger by a cable (not included).
Larger photo of data acquisition alarm MP002 Telephone voice dialer for alarm reporting, ac/dc adapter included. Enables in ALARM OUT output activity to send voice report to selected telephone numbers. Voice dialer is connected to land line.
Output relays module
Larger photo MP018 Output relays module with interconnection cable. It contains 16 mains relays 250V/8A with switching-over contacts. Each relay can be control based on alarm creatione at different input channels accordingly to setting of user program. Output relays are designed for external devices control (switching of heating, cooling, ventilation, distant alarm etc.). It is necessary to order connection cable to data logger MP017, optionally other accessories.
Larger photo MP017 Connection cable for terminal with display and output relays module - cable length approximately 60cm.
Longer cable lengths available - maximum 2m for relay module, maximum 50m for the terminal with display.
Larger photo of monitoring system holders MP013 Universal metal wall holders for data logger wall mounting. Package contains a pair of holders and 4 screws.
Larger photo of monitoring system holder MP019 Holder for relay module mounting to DIN 35mm rail. Package contains the holder and 6 plastic rivets.
Larger photo of monitoring system holder MP020 DIN rail for relay module with elevated consoles for mounting to the MP033, MP034 case. Rail enables to raise the relay module enables to lead cables to data logger under the module.
Terminals with display
Larger photo of data logger terminal MP016 Terminal with dual line alphanumerical LCD and control buttons and 32 alarm LEDs - for panel mounting or mounting to a case lid. Identical functions as built-in terminal of MS5D data logger. It is possible to build in with IP54 protection. Maximum cable length to data logger 50m. It is necessary to order the MP017 connection cable to data logger.
Larger photo MP017 Connection cable for terminal with display and output relays module - cable length approximately 60cm.
Longer cable lengths available - maximum 2m for relay module, maximum 50m for the terminal with display.
MP017-5 Connection cable for terminal with display - cable length 5m.
MP017-10 Connection cable for terminal with display - cable length 10m.
Larger photo of data logger terminal MP032 External terminal with dual line alphanumerical LCD and control buttons and 32 alarm LEDs - built in a IP54 protection case, including 2m cable with covered terminals. Identical functions as built-in terminal of MS5D data logger. Maximum cable length to data logger 50m.
GSM modem and accessories
Data logger modem - larger photo MP009 GSM modem WaveCom Fastrack M1306B, without accessories.
Data logger modem - larger photo MP009/1 Antenna for GSM modem WaveCom Fastrack, right-angled.
Larger photo of monitoring system cable MP009/2 Communication cable for GSM modem Fastrack.
MP009/3 Ac/dc adapter 230V/12V for GSM modem Fastrack.
Covers, cables and other accessories
Larger photo of data logger cover MP027 Covers of data logger terminals (pair). Designed for aesthetic covering of cables connected to terminals and connectors. Magnetic fixing to data logger.
Larger photo of data logger cable MP007 USB connection cable A-B, 1,8m.
Standard computer cable.
Larger photo of data logger connector MP030 RS232 connector with terminals for RS232 interface connection by means of terminals, not by D-Sub connector.
Larger photo MP031 Screwdriver for easy connection of cables to WAGO terminals.
Assemblies in case with higher IP protection
Larger photo of monitoring system case MP033 Case with IP65 protection with wall holders and data logger holders - no cutout in the lid.
Dimensions 270 x 570 x 140 mm.
Larger photo of monitoring system case MP034 Data logger MS5 in IP54 protection case with connected terminal with display built in the lid.
Dimensions 270 x 570 x 140 mm.
Connectable sensors and probes
Interior temperature, humidity, pressure transmitters Interior temperature, humidity, barometric pressure transmitters
outputs 4-20mA, RS485
Photo of humidity transmitter Industrial temperature, humidity, pressure transmitters Industrial temperature, humidity, barometric pressure transmitters
outputs 4-20mA, RS485
Photo of temperature probe Pt1000
Photo of temperature probe Pt1000
Pt1000 probes temperature probes with Pt1000/3850ppm sensor without connector - probe marking is followed by symbol /0
K thermocouple probes temperature probes with K thermocouple NiCr-Ni without connector - probe marking is followed by symbol /0

Ordering Form

Electronic form for easy selection of required monitoring system and accessories.
Send us please your filled Form as an e-mail attachment.
Run Ordering Form