Data acquisition system MS5D, MS5

Data acquisition system

The complete solution for monitoring of temperature, humidity and other values especially in following applications:

Single-channel to sixteen-channel data loggers are designed for recording of values from transducers of variety of quantities, alarm state indication, and process control. Datalogger with transducers configured accordingly to client order can measure analog signals, frequency, count impulses, evaluate two-state quantities and read data from devices compatible with ADAM Advantech protocol. Input signals are connected to removable terminal block located on the logger upper side. Analyzing of the record is enabled after data download to the personal computer by means of the included program via USB, RS232, Ethernet or GSM modem.

Free program for monitoring system for Windows is ready to download.

data-acquisition-system

New generation data acquisition system especially enables:

Following data loggers are available:

data logger - larger photo

MS5D

  • fully equipped data logger
  • dual line alphanumerical LCD display
  • four control buttons
  • 32 alarm LEDs
data logger - larger photo

MS5

  • all functions as MS5D
  • without LCD display, without control buttons, without alarm LEDs
  • alarm is indicated by one common LED.
TECHNICAL PARAMETERS OF DATA LOGGER
Memory type: internal SRAM, backed-up by Lithium battery
Total memory capacity: 2MB (up to 480 000 values)
Data logging mode: noncyclic - logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Data logging interval: adjustable individually for all input channels from 1 second to 24 hours
Real time clock: year, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Input measured values (1 to 16 inputs): are defined for each channel by installed input modules (see table) accordingly to user requirements
Resolution of the AD converter (analog channels): 16 bits, conversion duration approximately 60ms/channel
Supported interface for communication with computer:
  • RS232 (RxD,TxD,RTS,CTS,GND), cable up to 15 m - included. Enables direct connection with the PC or via line modem or GSM modem.
  • USB interface - included
  • RS485 - cable up to 1200 m, galvanically isolated, possibility of connection of several data loggers to one communication link - included
  • Ethernet interface LAN - optional. Communication via: SNMP, SOAP, www pages
Communication speed: 9600, 19200, 57600, 115200, 230400 Bd
Outputs for alarm indication: 1) Red LED at the side of the case, 32 LEDs - only MS5D data logger
2) Relay max. 8A/250Vac, switching-over contact
3) Voltage signal 0V/4.8V, maximum current 50mA, output designed for connection of external audio indication unit or telephone voice dialer
4) Alarm can be signalled also by e-mail message, SNMP trap, SMS - please see optional accessory
Power: 9 to 30Vdc, 24Vdc recommended
Operating temperature range: 0 to +50°C
Dimensions including connectors: 215 x 225 x 60 mm
Protection: IP20
Warranty: 2 years

Communication interfaces:

communication interfaces
TYPES OF INPUTS
TypeMeasured valueAccuracyNote
A0 dc current 4 to 20 mA ±0.1% FS With source approximately 21V for two-wire transducers with current loop (e.g. temperature and humidity transducers Comet). Only galvanic not isolated.
A1* dc current 4 to 20 mA ±0.1% FS for passive sensing of current
B0* dc current 0 to 20mA ±0.1% FS  
B1* dc current 0 to 1A ±0.1% FS  
B2* dc current 0 to 5A ±0.1% FS  
C0 ac current 0 to 20mA ±1% FS galvanic isolated
C1 ac current 0 to 1A ±1% FS galvanic isolated
C2 ac current 0 to 5A ±1% FS galvanic isolated
D0* dc voltage 0 to 100mV ±0.1% FS  
D1* dc voltage 0 to 1V ±0.1% FS  
D2* dc voltage 0 to 10V ±0.1% FS  
D5* dc voltage -10V to +10V ±0,1% FS
(± 20 mV)

New!

D4* dc voltage 0 to 75V ±0.1% FS

New!

E0 ac voltage 0 to 100mV ±1% FS galvanic isolated
E1 ac voltage 0 to 1V ±1% FS galvanic isolated
E2 ac voltage 0 to 10V ±1% FS galvanic isolated
E4 ac voltage 0 to 50V ±1% FS

New!


galvanically isolated
F* measurement of resistance (specify the range) ±0.1% FS two-wire connection
J* input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50 to +250°C -50 to 100°C ±0.2°C 100 to 250°C ±0.2% from reading  
K* input for Platinum RTD temperature sensor Pt100, range -140 to +600°C -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading two-wire connection
K1* input for Platinum RTD temperature sensor Pt1000, range -140 to +600°C -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading two-wire connection
K3 precise input for Platinum RTD temperature sensor Pt1000
range -10 to +50°C
±0.06°C

New!

Two-wire connection.
Only galvanically not isolated.
N* thermocouple K (NiCr-Ni) range -70 to +1300°C ±(0.3% + 1.5°C) from reading linearized, cold junction compensation
T* thermocouple T (Cu-CuNi) range -200 to +400°C ±(0.3% + 1.5°C) from reading linearized, cold junction compensation
O* thermocouple J (Fe-Co) range -200 to 750°C ±(0.3% + 1.5°C) from reading linearized, cold junction compensation
P* thermocouple S (Pt10%Rh-Pt), range 0 to 1700°C ±(0.3% + 1.5°C) from reading from +200 to +1700°C linearized, cold junction compensation
Q* thermocouple B (Pt30%Rh-Pt), range +100 to +1800°C ±(0.3% + 1°C) from reading from +300 to +1800°C linearized, without cold junction compensation
S* binary input for potential-less contacts maximum resistance of closed contact: 1000 ohms minimum duration for recording: 200ms
S1 binary voltage input voltage for "switched ON" state: 3 to 30Vdc, input current in the"switched ON" state: 1 to 9mA-depending on the applied voltage, minimum duration for indication of change: 200ms, galvanic isolated
CTU counter input for voltage signal voltage for "HIGH" state (for counter status change): 3 to 24Vdc maximum pulse frequency 5kHz, backed-up operation, galvanic isolated
CTK counter input for potential-less contacts and open collector maximum pulse frequency 5kHz, programmable filter of pulse ringing, backed-up operation during power mains failure, maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, galvanic unisolated
FU input for measurement of frequency of voltage signal 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) input voltage for state "H": 3 to 24Vdc input current in state "H": approximately 7mA minimum duration of input impuls: 30us, galvanic isolated
FK input for measurement of frequency of contact switching 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, minimum duration of input pulse: 30us, galvanic unisolated
RS input for serial signal RS485 for devices supporting Advantech protocol e.g. measurement from transmitters with RS485 digital output connected to the serial RS485 network - ADAM Advantech protocol , galvanic isolated

Input module for monitoring system

Input module A0 4-20mA

Input module for monitoring system

Counter input module CTU

Larger photo of monitoring system

View of power and communication connectors

Larger photo of monitoring system

View of power and input connectors
- three terminals/input


Notes: Inputs marked ( * ) are not galvanic isolated and have common ground. These inputs are available also as galvanic isolated. Galvanic isolated analog inputs are marked with letter G following the name of input type (e.g. input for passive measurement of current 4-20mA - type A1 - with galvanic isolation is marked A1G). Galvanic isolation is not designed as safety protection.

Accessories

Data Sheet in pdfData Sheet in pdf
Basic Manual in pdfBasic Manual in pdf
Manual in pdfManual Appendixes in pdf