Main thermometer applications:
- Transport of food or pharmaceuticals - tested by accredited laboratory in accordance with the European standard EN 12830 - Temperature recorders for transport, storage and distribution of chilled, frozen food.
- Food and beverage industry (HACCP)
- Pharmaceutical industry
- Blood stations, pharmacies
- Horticulture and cultivation of plants
- HVAC (heating, ventilation, air conditioning, cooling)
- Building and energy management
- Research and development
- Laboratories (GLP)
- Warehouses
- Technological processes
- Museums, archives, galleries
Thermometer advantages:
- included traceable calibration certificate from the manufacturer - Comet
- fast data transfer to the PC (full memory for approximately 30s)
- variability of connection to the computer - USB, RS232, Ethernet, GSM modem
- permanent connection to the PC enabled, data is possible to download even during logging
- large data memory 32000 values
- large dual line display with special symbols, switchable
- optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
- dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display or LED diode
- two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is cleared from the PC)
- robust watertight case
- easy installation, locking enabled
- low power consumption from battery, battery life up to 7 years
- indication of remaining battery life, easy replacement of the battery
- standard temperature sensor is Pt1000/3850ppm, switchable to Ni1000/6180ppm external probes at range -50 to +150°C
- it is possible to combine temperature measurement with logging of contact state (e.g. door contact)
- logging start/stop is enabled in several ways: at certain time and date programmed from computer, by delivered magnet or depending on binary input state (type S0841)
- also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm limits
- each logger is possible to describe with text of maximum 32 characters
- each channel is possible to describe with text of maximum 16 characters
- password protection is enabled to prevent unauthorized manipulation with logger
COMMON TECHNICAL PARAMETERS | |
---|---|
Operating temperature range of loggers R0110, R0110E without display: | -40 to +80°C logger R0110 -30 to +70°C logger R0110E |
Operating temperature range of loggers S0xxx with display: | -30 to +70°C |
Accuracy of the Pt1000/3850ppm input without probe - loggers S0xxx : | ±0.2°C from -50 do +100°C ±0.2% from reading from +100 to +260°C ±0.4% from reading from –90 to –50°C |
Accuracy of temperature measurement of internal sensor: | ±0.4°C (except economy model R0110E) |
Resolution of the reading: | 0.1°C |
Real time clock: | year, leap year, month, day, hour, minute, second |
Data logging interval: | adjustable from 10s to 24h |
Display and alarm refresh: | each 10 s |
Total memory capacity: | 32000 values in noncyclic logging mode |
Data logging modes: | noncyclic – logging stops after filling the memory cyclic – after filling memory oldest data is overwritten by new |
Dimensions without connectors: | loggers with display 93x64x29mm loggers without display 93x64x26mm |
Power: | Lithium battery 3,6V, size AA |
Typical battery life in operation from -5 to +35°C: | 7 years R0110, R0110E 6 years S01xx 5 years S0141 and S0841 |
Battery life in continuous on-line mode with interval 1 minute: | reduced to 70% of the above lives |
Battery life in continuous on-line mode with interval 10 seconds: | 1 year |
Protection: | IP67 - protected against influence of temporary immersion into water |
Warranty: | 2 years |
THERMOMETERS WITH LCD DISPLAY | ||||
---|---|---|---|---|
Thermometer model | Measured signals | Measuring range | Manual in pdf format | |
S0110 - single channel thermometer with internal sensor | 1xT | -30 to +70°C | ||
S0110E - economy single channel thermometer with internal sensor with measurement accuracy: ±0.6°C from -30 to +30°C ±0.8°C from +30 to +70°C. |
1xT |
-30 to +70°C
New ! Low cost ! |
||
S0111 - single channel thermometer for temperature logging from one external probe | 1xT | -90 to +260°C | ||
S0121 - dual channel thermometer for temperature logging from two external probes including temperature difference between channels | 2xT | -90 to +260°C | ||
S0122 - dual channel thermometer for temperature logging from internal sensor and external probe including temperature difference between channels | 2xT |
internal -30 to +70°C external -90 to +260°C |
||
S0141 - four channel thermometer for temperature logging from four external probes. Thermometer has Type approval certification in accordance with EN 12830 - Temperature recorders for transport, storage and distribution of chilled, frozen food. |
4xT | -90 to +260°C | ||
S0541- four channel thermometer for temperature logging from two external probes. Additional universal inputs for two voltage signals 0-5Vdc (accuracy ±0.2% FS). Necessary to order K1321 connectors for connection of input signals 0-5V. | 2xT + 2x 0-5Vdc |
-90 to +260°C
New ! - e.g. monitoring of battery voltage and temperature - other voltage range on request |
||
S0841- dual channel thermometer for temperature logging from two external probes, including temperature difference between channels. Additional inputs for two binary signals, e.g. from door contact. | 2xT + 2xbinary | -90 to +260°C |
THERMOMETERS WITHOUT LCD DISPLAY | ||||
---|---|---|---|---|
Thermometer model | Measured signals | Measuring range | Manual in pdf format | |
R0110 - single channel thermometer with internal sensor. Thermometer has Type approval certification in accordance with EN 12830 - Temperature recorders for transport, storage and distribution of chilled, frozen food. |
1xT | -40 to +80°C | ||
R0110E - economy single channel thermometer with internal sensor with measurement accuracy: ±0.6°C from -30 to +30°C ±0.8°C from +30 to +70°C. Thermometer has Type approval certification in accordance with EN 12830 - Temperature recorders for transport, storage and distribution of chilled, frozen food. |
1xT | -40 to +80°C |
Common manual for quick start of all Sxxxx, Rxxxx data loggers
Data loggers are delivered without external temperature probes. To order probes with Pt1000 sensor see Optional accessory.
Thermometer R0110
with wall holder
Accessories
Included is traceable calibration certificate from the manufacturer, instruction manual.
Calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Example of calibration certificate.
For thermometer basic use it is necessary to order at minimum a COM adapter or USB adapter for communication with computer, optionally a start/stop magnet, if needed to control logging the other way than directly from computer. Also connector(s) for binary signals connection to S0841 data logger is necessary to order
Anytime it is possible to download free basic program for Windows. Program enables to control all logger functions and viewing and printing of record in numerical and simple graphic format. It is possible to export recorded temperature values to dbf or txt formats for further analysis.
OPTIONAL ACCESSORIES | ||
---|---|---|
SWR004 | optional software for Windows - color printing, vertical and horizontal zooming of graphs and other functions. | |
SW100 | CD with free PC program | |
LP002 | COM adapter for communication with personal computer via RS232 serial port | |
LP003 | USB adapter for communication with personal computer via USB port | |
LP005 |
LAN adapter - external converter for communication with the PC via Ethernet, including ac/dc adapter 230Vac/5Vdc.
Exceeding of adjusted limits is alarmed by sending e-mail message or trap. More information in manual in pdf format |
|
LP004 | start/stop magnet | |
MD036 | self adhesive Dual Lock for easy installation | |
F9000 | wall holder secured against unauthorized removal | |
A4203 | spare Lithium battery 3.6V size AA | |
K1321 | female connector for connection of S0841 logger binary signal, protection IP67 | |
|
probes | for types S0111, S0121, S0122, S0141, S0841 it is necessary to order temperature probes with RTD Pt1000 sensors equipped with female K1321 connectors - there is a symbol /E behind probe name. |
LP006 | GSM adapter for communication via GSM modem WaveCom Fastrack | |
MP009 | GSM modem WaveCom Fastrack M1306B, without accessories | |
MP009/1 | antenna for GSM modem WaveCom Fastrack, right-angled | |
MP009/2 | data cable for GSM modem Fastrack adjustment | |
MP009/3 | ac/dc adapter 230V/12V for GSM modem Fastrack |
Temperature recorders with built-in printer |