Carbon Dioxide Concentration Trasmitters
with Relay and RS232 Outputs
Humidistat H3331, H7331
- temperature
- barometric pressure
- relative humidity
- dew point temperature
- absolute humidity
- specific humidity
- mixing ratio
- specific enthalpy
- three binary inputs
Humidistats are designed for two-state control of e.g. heating, ventilation, humidifier, dehumidifier, etc.
Transmitter is equipped with two relay outputs for alarm indication or control of external devices. Each relay can be assigned to any measured or computed value.
For each relay setting of delay, hysteresis, audible alarm is enabled.
Measured values are converted to RS232 serial output.
Fully equipped transmitter contains temperature, humidity, pressure sensors.
Measured temperature and relative humidity is recalculated to other humidity interpretations - dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy.
Reading and pressure output are available in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2. Degrees Celsius and Fahrenheit are user selectable.
Parameters are easy adjustable from regulator keyboard or from the computer.
Large dual line LCD for simultaneous display of temperature, pressure or relative humidity or other calculated humidity interpretation is an advantage.
State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitter is designed for use in non-aggressive environment.
Transmitter is also equipped with three binary inputs for detection of two-state events - e.g. water, smoke, glass break detection, door contact.
HUMIDISTAT APPLICATIONS
- temperature and humidity control
- monitoring of temperature, humidity, pressure and three binary signals at:
- building management and automation
- server rooms
- telecommunication devices
- warehouses, glasshouses
- manufacturers
- museums, archives, galleries
- air-conditioned rooms, HVAC
- weather stations
H5324 CO2 concentration transmitter
Carbon Dioxide concentration transmitters
The CO2 - carbon dioxide level is recently regarded as an important parameter that substantially determines the quality of the interior climate. Especially in buildings where many people gather, such meeting rooms, hospitals, schools, cinemas, theatres and care centres. With the help of CO2 sensor engineers, technical advisors, environmental experts and health specialists can optimize the ventilation for creation of a healthy interior climate.The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell.
The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.
APPLICATIONS - measuring of CO2 level at:
- building HVAC management
- climate technology
- schools, universities
- meeting rooms, hospitals, cinemas, theatres
- weather stations
Parameters are easy adjustable from regulator keyboard or from the computer.
Transmitter contains a microprocessor based control circuitry in a durable plastic case with connection terminals.
The CO2 concentration sensor is built inside the case.
Large dual line LCD is an advantage. Display is possible to switch off. Computerized design ensures maximum long term stability and failure indication.
Measured CO2 concentration values are converted to RS232 serial output.
Serial output RS232 - transmitter works with ModBus RTU communication protocol or with Advantech ADAM compatible protocol. Protocol is user selectable in special configuration mode by means of the PC. Serial link enables to read actual readings and modify transmitter configuration. Instrument works always in slave mode, i.e. responds only to master device query. Transmitters have the address space available from 1 to 255. Communication speed is 110 to 115200Bd.
COMMON TECHNICAL PARAMETERS | |
---|---|
Maximum switching voltage, current, power of relay output: | 50V, 2A, 60VA |
Audible alarm: | from built-in beeper - switchable |
Supported temperature units: | degrees Celsius, degrees Fahrenheit |
Accuracy of temperature measurement: | ±0.4°C from -30 to +100°C, ±0.4% from reading over +100°C |
Range of relative humidity measurement: | 0 to 100% |
Accuracy of relative humidity measurement: | ±2.5% relative humidity from 5 to 95% at 23°C |
Accuracy of temperature measurement: |
±0.4°C from -30 to +100°C ±0.4% from reading over +100°C |
Accuracy and measuring range of dew-point temperature: - for more details see graphs |
±1,5 °C at ambient temperature T < 25°C and RH>30% range -60 to +80 °C |
Accuracy and measuring range of absolute humidity: | ±3g/m3 at ambient temperature T < 40°C range 0 to 400 g/m3 |
Accuracy and measuring range of specific humidity: | ±2g/kg at ambient temperature T < 35°C range 0 to 550 g/kg |
Accuracy and measuring range of mixing ratio: | ±2g/kg at ambient temperature T < 35°C range 0 to 995 g/kg |
Accuracy and measuring range of specific enthalpy: | ± 3kJ/kg at ambient temperature T < 25°C range: 0 to 995 kJ/kg |
Operating temperature range of the case with electronics: | -30 to +80°C |
Operating temperature range of LCD display: | readable up to operating temperature +70°C, it is recommended to switch off LCD over +70°C |
Range of temperature compensation of RH sensor: | -30 to +125°C |
Signal for binary inputs: |
from voltage-less contact, open collector or two-state voltage signal. Inputs are not galvanically isolated. |
Minimum pulse length at binary input: | 500 ms (shorter pulse may not be detected) |
Voltage at open contact: | 3.3 V |
Low voltage level: | 0 to +0.2 V |
High voltage level: | +3.0 to +30V |
Filtering ability of sensor cover: | 0.025mm - filter from stainless steel mesh |
Protection - temperature and humidity transmitters: |
IP65 electronics with terminals, IP40 humidity sensors |
Protection - transmitters measuring pressure: |
IP54 electronics with terminals, IP40 humidity and temperature sensors |
Power: | 9-30Vdc |
Dimensions of the case: | 135 x 136 x 45 mm (W x H x D) |
Warranty: | 2 years |
COMMON TECHNICAL PARAMETERS FOR CO2 TRANSMITTERS | |
---|---|
Output | RS232 |
Measured Value | CO2 |
Construction Type | Ambient Air |
Design | Industrial |
Temperature Measuring Range | None |
Relay Output | Yes |
Two-State Input | No |
Lcd Display | Yes |
Maximum switching voltage, current, power of relay output | 50V, 2A, 60VA |
Audible alarm | from built-in beeper - switchable |
Range of CO2 concentration measurement | 0 to 2000ppm |
Accuracy of CO2 concentration measurement | ±(50ppm +2% from reading) at 25°C and 1013hPa |
Optional range of CO2 concentration measurement | 0 to 10000ppm ±(100ppm +5% from reading) at 25°C and 1013hPa |
Temperature operating range | -30 to +60°C |
Measuring interval of CO2 | 15s |
Communication protoco | ModBus RTU and Advantech ADAM compatible protocol |
Communication speed | 110 to 115200 Bd |
IP protection | IP30 |
Power | 9-30Vdc, power consumption approximately 1W |
Dimensions | 136 x 150 x 45 mm (W x H x D) |
Weight | approximately 360g |
Warranty | 2 years |
Humidistats are available in the following models:
Model | Measured value | Maximum measuring ranges | Stem length | Output | Other output | Description |
---|---|---|---|---|---|---|
H4331 |
temperature+ 3binary inputs |
-200 to +600°C | - | 2xRelay | RS232 |
Temperature transducer for RTD Pt1000probes (not included). Accuracy of the input without probe +/-0,2°C |
H3331 |
temperature+ humidity+ 3binary inputs |
-30 to +105°C* probe incl. cable | probe cable 1,2,4m | 2xRelay | RS232 | T+RH probe with 1m cable. Cable lengths 2m or 4m available optionally. |
H7331 |
temperature+ humidity+ atm.pressure+ 3binary inputs |
-30 to +105°C* probe incl. cable | probe cable 1,2,4m | 2xRelay | RS232 |
T+RH probe with 1m cable. Cable lengths 2m or 4m available optionally. Pressure sensor is located in the control unit with display.
Reading and pressure output in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in^2. Barometer enables to measure sea level pressure by setting of correction to altitude above sea level. |
CO2 concentration transmitters are available in the following models:
Description of communication protocol in pdf
CO2 concentration transmitter datasheet in pdf
* Relative humidity at temperature over +85°C is limited in accordance with the graph. Near plastic case with electronics and probe cable maximum temperature is +80°C.
Figure: Humidistat working range
Serial output RS232. Transmitter works with ModBus RTU communication protocol or with Advantech ADAM compatible protocol. Protocol is user selectable in special configuration mode by means of the PC. Serial link enables to read actual readings and modify transmitter configuration. Instrument works always in slave mode, i.e. responds only to master device query. Transmitters have the address space available from 0 to 255. Communication speed is 110 to 115200Bd.
Free program SensorReader for logging values from one transmitter via RS232 to a PC disk file is ready to download. Program enables to alarm acoustically the PC user if adjusted alarm limits are exceeded. Recorded values in CSV format are easy to process in e.g. Excel. Program can be started several times on a computer at the same time to monitor values from several transmitters.
Included accessories:
Traceable calibration certificate from the manufacturer, instruction manual.
Calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Example of calibration certificate.
Free program TSensor for configuring of the transmitter is ready to download.
For acquiring values from several transmitters connected to RS232 link, third party software is necessary to use. Tested functionality is with programs:
LabVIEW from National Instruments,
TIRS.NET,
ControlWeb,
EasyView.
HUMIDISTAT OPTIONAL ACCESSORY | ||
---|---|---|
GSM monitoring system |
Preliminary ! Wireless online monitoring system with sensors via GSM |
|
F5200B | black sensor cover with filter from stainless steel mesh, filtering ability 0,025mm | |
F0000 | sintered bronze sensor cover. Filtering ability 0.025mm. | |
PP4 | flat plastic circular flange for duct mounting | |
PP90 | right-angled stain-less steel flange for wall mounting | |
SP004 | plastic gland for direct mounting of the humidity probe to a 29 mm diameter hole | |
MD036 | self adhesive Dual Lock for easy installation | |
SP006 | Tool for easy wire connection to terminals | |
A1510 | adapter 230V-50Hz/12Vdc | |
F8000 | Solar radiation shield for transmitters H3431, H7431 with T+RH probe on a cable | |
accessory for calibration and adjustment of humidity by the user |
OPCIONAL ACCESSORIES FOR CO2 CONCENTRATION TRANSMITTERS | ||
---|---|---|
A1510 | For serial Txxxx output transmitters and Hxxxx transmitters - for connection to terminals | |
MP006 | RS232/USB converter for communication with the PC via USB port. | |
SP006 | Tool for easy connection to WAGO terminals 233 for serial output transmitters |
Ethernet temperature, humidity, pressure sensors | Low cost temperature, humidity, pressure sensors |